Operation steps
1. First select the model of the target chip
2. Open the program code file
3. Set the corresponding hardware options
4. Try burning the chip and write down the ID number of the target chip.
(If you do not need to verify the ID number of the target chip, you can skip this step)
5. Set automatic increment (if you do not need automatic increment, you can skip this step)
6. Set 485 control information (if you do not need 485 control, you can skip this step)
7. Set user-defined download command (if you do not need this function, you can skip this step)
8. Click the "Read local hard disk number" button on the interface and write down the hard disk number of the target computer
(If you do not need to verify the hard disk number of the target computer, you can skip this step)
9. Click the "Publish Project Program" button to enter the setting interface for publishing applications.
10. According to your own needs, modify the title of the released software, the name of the download button,
Repeat download button name, auto-increment name and help information
11. If you need to verify the hard disk number of the target computer, you need to check "Verify hard disk number".
And enter the hard disk number of the target computer written down earlier in the following text box.
12. If you need to verify the ID number of the target chip, you need to check "Verify Chip ID Number".
And enter the ID number of the target chip written down earlier in the following text box.
13. Finally, click the Publish button to save the project publishing program to get the corresponding executable file.
Things to note
The functions of verifying the hard disk number and verifying the target chip ID number are only for the following series:
Valid for new microcontrollers:
STC15F2K60S2/STC15L2K60S2
IAP15F2K61S2/IAP15L2K61S2
STC15F104W/STC15L104W
IAP15F105W/STC15L105W
STC15W104SW/IAP15W105W
STC15W201S/IAP15W205S
STC15F408AD/STC15L408AD
IAP15F413AD/IAP15L413AD
Change log
Ver6.85H (2015-6-16)
1. Support PL2303 for simulation
2. Fix incompatibility issues of published projects
3. Add support for STC15H4K64S4 model (testing phase)
Ver6.85G (2015-5-3)
1. Internal beta version
Ver6.85F (2015-5-27)
1. The checksum of code files and data files is increased to 3 bytes.
2. Add support for PL2303 when downloading from ISP (the emulation of some domestic compatible chips is not yet supported)
Ver6.85E (2015-5-15)
1. Fixed the problem when U8 tool downloads old firmware versions of the following models offline
IAP12C5A60S2 (firmware version 6.2I or 6.5I)
IAP12LE5A60S2 (firmware version 6.2I or 6.5I)
IAP11F60XE (firmware version 6.2L or 6.5L)
IAP11L60XE (firmware version 6.2L or 6.5L)
2. Strengthen the encryption of released project files