The goal is to promote the standardization, Chinese culture, and digitization of reports in small and medium-sized laboratories. Provide a comfortable operating platform for inspection workers. The author wrote this system based on the working habits and software needs of laboratory departments that he learned through several years of work research. It is very suitable for the operating habits of small and medium-sized laboratories.
Some examples of functions:
·Customized report format: Place each content anywhere on the report sheet as you like, such as moving patient information to the left side of the report and moving the results to the right side. You can set the color of results printed when the result is elevated or the color printed when the result is positive. For example, if the positive specimen result is printed in red, it is clear at a glance... there are too many, four words, you can do whatever you want. 9999 report formats can be stored, and the report date can be freely selected to be accurate to hours, minutes, and seconds. You can also add hospital icons or promotional images to the report card.
·Data security function: It can store more than 3 million data, and the database has been tested with 3 million records and runs normally and quickly. Automatically compress and organize the database every two months. Automatically back up daily report data in a separate directory, so you can sit back and relax.
·Powerful query function: You can customize various conditions for query, and what’s more, you can query through the results. This function is widely used in statistical summary such as Dasanyang. For example, if you select records that meet the results of major three positives within a period of time, perform statistics, summary, and retention...·Statistical function: you can count the charges separately according to the department, examiner, and doctor who submitted the examination, and you can even count the charges according to each individual Project statistics.
·Quality control function: Quality control results can be automatically stored in the database after receiving data from the instrument, or can be entered manually. A certain report result can also be transferred to the quality control database, which is extremely convenient. Quality control charts can be drawn for any period of time, unlike ordinary software that can only draw quality control charts for a certain month.
·Project settings: Different types of reference values can be set, such as reference values for different ages, different genders, and different specimen types. When displaying and printing reports, it is automatically judged to increase or decrease based on the set reference value. Calculation item formulas can be set to automatically calculate relevant calculation items after receiving data from the instrument or manually inputting data. For example, automatically calculating GLB and A/G after manually inputting or receiving TP and ALB results from the instrument. What's even better is that you can set up n-th power calculations, such as calculating the INR value of blood coagulation. If you manually enter the PT results, the INR value can be automatically calculated.
·System log function: record the running status of the software in detail, such as login time and exit time.
·Input control settings: You can freely set the input method status when entering patient information to avoid frequent switching between Chinese and English input methods. You can also set which text boxes to skip directly, greatly improving the input speed.
·Combination input settings: 20 inspection combinations can be customized, which is very useful for manual report input. If you have preset a two-and-a-half combination, press CTRL+F1 to quickly add five results.
·Powerful online help function: Press F1 anytime, anywhere to quickly open the help information of the corresponding interface.
·Summarize the record-keeping function: end the history of hand-written records by inspection workers.
·View history record function: historical results can be viewed based on patient ID number. For outpatients without ID numbers, all historical results can be automatically viewed based on name for reference.
·Convenient and user-friendly shortcut key design: Most commonly used functions have shortcut keys. It eliminates the complicated operation of moving the mouse for a while and moving the keyboard for a while. The operation interface changes the shortcomings of traditional software's large number of pop-up prompt boxes (you have to click "Close" every time a pop-up occurs to continue other operations). Some common prompts are displayed in flashing text, which does not affect the input operation.
·Can receive data from up to eight instruments at the same time: For example, a small laboratory department can use a computer to connect blood cells, biochemistry, and urine routine instruments. If the communication port is not enough, a USB-COM conversion cable can be used.