Contents of limited space operation management system
1. Departments that enter confined space operations apply for a "Confined Space Entry Permit."
2. The person in charge of the operating department shall confirm and sign the operating procedures and corresponding safety measures, and the Minister of Safety and Environmental Protection will issue a "Permit for Entering Confined Space Operations" for approval. In the absence of the Minister of Safety and Environmental Protection, the supervisor shall issue and approve it.
3. The person in charge of the operation department and the safety administrator should explain the operation procedures and safety measures to the workers, and assign operation guardians to conduct on-site supervision of the entire process of confined space operations.
4. After the confined space operation is completed, the person in charge of the operation shall cooperate with the operation guardian to conduct completion acceptance and sign in the completion acceptance column of the "Confined Space Entry Permit".
Precautions for limited space operation management system
Before entering a limited space for work, the limited space must be cleaned and replaced, and the following requirements must be met:
Before cleaning, workers must be familiar with the physical and chemical properties of substances present in a limited space and the safety technical instructions of related materials.
When cleaning, you should first use inert gases such as nitrogen to protect or replace flammable, explosive or toxic and harmful media; then, use steam or hot water as the cleaning medium. There should be no blind ends during cleaning, and the cleaning order is from high to low. If there are materials that are difficult to clean with steam or hot water, appropriate solvents should be used for cleaning, with non-toxic substances preferred; clean them with steam or hot water again.
After cleaning, air replacement should be carried out, and the levels of oxygen and other dangerous gases should be monitored at any time.
When using compressed air for replacement, blind end replacement should be considered, and the flow rate should be controlled to less than 2 cubic meters/minute.
The oxygen content after replacement should reach 18-21%.
The concentration of toxic, harmful and other dangerous gases in limited spaces complies with GB Z2-2002 regulations.