Weteng Professional Intelligent Access Management SystemFunction introduction
Supports the mother card function: using the mother card can quickly and easily authorize other cards, and the mother card itself can also be used alone.
How to open the door: swipe card or password to open the door (4 groups)
Methods to register and authorize new cards: support manual keyboard input to add cards, parent card to add cards, and card issuer to add cards
Network remote door opening: supported
Door opening delay: Default 3 seconds, adjustable from 0-600 seconds
Comes with a precise clock, and can quickly calibrate time with one click on computers and other external devices. Built-in long-lasting lithium battery, clock settings will not be lost during power outage.
Door status monitoring: You can remotely see whether the door is open or closed. (Door sensor or electric lock with door sensor needs to be installed)
Events such as card swiping, button opening, and door opening can be recorded and queried, and all records include real-time time. No power outage records and settings will be lost.
Enter the security mechanism with your username and password.
Comes with installation-free green management tool software, which can be set up with one click, fast and convenient.
Supports fast fuzzy search of card numbers and names.
It supports almost all Wiegand international standard protocol RF card readers on the market, allowing customers to choose their favorite card reader appearance. Supports password keyboard card reader and has the function of opening the door with up to 4 sets of passwords.
Weteng Professional Intelligent Access Management SystemSoftware features
Quickly add controllers through search
Add card holders by swiping the card
Add permissions to allow and upload
The setting column includes the relevant function settings of the controller
Add and modify department information
Select the relevant permission functions of the user
Supports the rapid addition of advanced departments
Support original records for quick query
Weteng Professional Intelligent Access Management SystemInstallation steps
1. Download the software, unzip it, double-click the installation file, enter the installation interface, and click Next
2. Select the installation folder and click Next
3. Confirm installation and click Next
4. Installing...
5. The software is installed successfully, click Finish
Weteng Professional Intelligent Access Management SystemInstructions for use
User login:
Click Start>Programs>Professional Intelligent Access Management System>Professional Intelligent Access Management System or double-click the shortcut of the desktop key icon to enter the login interface.
Enter the default username: abc and password: 123 (note: use lowercase for the username). The username and password can be changed in the software.
Add device:
To add a device, click [Controller] to enter the controller interface.
Click [Add] to define the controller in the system.
[Product serial number]: The unique serial number of each controller. You can find S/N:********** on the label of the controller circuit board. Please enter the 9-digit number you found. Fill in.
Remarks: If the serial number filled in does not match the serial number checked on the controller, the controller will not be able to communicate normally with the access management system.
【Small LAN [same network segment]】: Supports TCP/IP communication, suitable for situations where all access controllers are in the same network segment.
[Medium and large LAN [across network segments] or the Internet]: Supports TCP/IP communication, suitable for situations where the access control controller is in different network segments and the network is relatively complex. This IP must be specified by the customer themselves.
After setting up, click [Next]
Note: After the settings are completed, [Upload Settings] must be performed at [Operation] > [Main Console].
Click [OK] to complete adding the controller.
Note: If you need to replace the controller, you can directly use the product serial number of the new controller to change it. Original product serial number. Please note that replacement requires the same model number. After replacement, all settings and permission information will not change after [Upload Settings] on the main console.
Weteng Professional Intelligent Access Management SystemFAQ
1. Place the valid card close to the card reader. The buzzer will sound and the LED indicator will turn green, but the door lock will not open. What are the possible reasons?
answer:
(1) The wiring between the controller and the electric lock is incorrect;
(2) Whether the power supply of the electric lock is normal. The normal output voltage of the power supply is about DC12V. If the voltage is too low, such as below DC11V, it may cause the relay of the access control controller to be unable to be driven, resulting in card swiping or button failure to open the door; if the access control software is used for real-time monitoring, the phenomenon displayed at this time will be There is a record of opening the door by swiping the card and allowing passage;
(3) Electric lock failure; the electric lock itself is abnormal, such as the lock tongue is mechanically stuck or damaged.
2. The card reader has been used normally for a period of time, but it is found that it does not read the card or emits abnormal sound and light prompts. What are the possible reasons?
answer:
(1) The controller is faulty. Certain faults in the controller may cause the card reader corresponding to the controller to be abnormal, such as a clock failure. Whether the controller is faulty can be judged by the detection information of the software or by checking whether the ERR fault indicator light on the controller motherboard is flashing. (The ERR indicator light is off under normal circumstances). If the software detects that the controller has a clock failure, first calibrate the time of the controller. If it is normal after calibration, it means that the controller is not faulty, otherwise the controller needs to be repaired;
(2) The card reader is subject to on-site interference. The phenomenon is that the card reader is only connected to the power supply and tested separately, and the card reader is normal. In this case, it is necessary to first understand the on-site environment, such as: whether the AC220V power supply of the controller chassis is connected to a three-core wire and whether it is truly grounded; whether the load of the power supply is too large; whether the distance between the card readers is too close, such as back-to-back installation level The spacing distance is less than 30 cm; the card reader is installed directly on the metal surface without hollowing out the metal surface under the card reader or raising the card reader; whether there are high-power equipment around the card reader, etc.;
(3) The card reader is damaged. The phenomenon is that the card reader is only connected to the power supply and tested alone. If the card reader is still abnormal, the card reader needs to be repaired.
Weteng Professional Intelligent Access Management System Update Log
1. The details are more outstanding!
2.BUG gone without a trace
Huajun editor recommends:
Of course, in addition to the micro-farming professional intelligent access control management system, our Huajun Software Park also has other very convenient software for other industries.Leyi integrated ceiling design software,Log volume calculator,Guangdong Provincial Enterprise Income Tax Declaration System,Agricultural Bank of China Certificate,Taiyou CPK calculation toolRelated software is available for download. If you need it, please click to download and use it.