o (心) o sadness

WeChat cannot be downloadedModbus debugging tool (Modscan32), But just click on the upper right corner to select it in the browser or Safari!
Modbus debugging tool (Modscan32)

Modbus debugging tool (Modscan32)

  • Size: 2.19m
  • Language: Simplified Chinese
  • category: Other industries
  • System: WINALL

Recommend for you: Modbus debugging tool Modbus debugging tool (Modscan32)

Modbus debugging tool (Modscan32)The official version is a Modbus debug assistant suitable for the computer. The official version of the Modbus debugging tool (Modscan32) supports the Modbus protocol device debugging operation, which can receive important data information of the Modbus protocol. andModbus debugging tool (Modscan32)It is also written in VC and does not require any other files when running. Huajun Software Park provides downloading services for Modbus debugging tools (MODSCAN32), and other versions of Modbus debugging tools (Modscan32), please go to Huajun Software Park!

Modbus debugging tool (Modscan32) software function

1. You can automatically display the received data

2. You can debug all devices with the MODBUS protocol

3. You can set the data sent regularly and time interval

4. You can simulate the use of the Modbus protocol host for the upper machine. The Modbus debug the elves are written in VC and do not need any other files when runtime.

5. Support Hex or ASCII code display. It is an essential tool for engineering and technical personnel to monitor and debug serial procedures.

6. You can set up various communication rates, puppets, and communication ports without need to restart the program. Send data to send the hexadecimal (Hex) format and ASCII code.

Modbus debugging tool (Modscan32) software characteristics

1. Modbus can support a variety of electrical interfaces, such as RS-232, RS-485, etc., and can also be transmitted on various media, such as twisted lines, fiber fiber, wireless, etc.

2. The frame format of Modbus is simple, compact, and easy to understand. Users are easy to use, and manufacturers have simple development.

3. Standards and openness, users can use the MODBUS protocol for free and safely. There is no need to pay a license fee or infringe intellectual property rights. At present, there are more than 400 manufacturers supporting Modbus and more than 600 products that support Modbus.

Modbus debugging tool (Modscan32) installation steps

1. Download the Modbus debugging tool (MODSCAN32) in Huajun Software Park to get a software compressed package.

2. Then decompress the software to get the Modscan32.exe in it.

3. Finally, double -click to open the Modscan32.exe, you can use it.

Modbus debug tool (Modscan32) instructions

Set the data bit to 8 bits, stop bit to one bit, and use the Modbus collection window below

Collect the intelligent number display instrument class:

If the measuring value of the collection PV is entered 010400000001? The collection HIAL value is input 010300010001?

Through and so on ...

Collect the intelligent PID regulator instrument class:

If the measuring value of the collection PV is entered 010400000001? The collection SV value is input 010300000001?

Collect the measurement value of the inspection instrument:

Enter 010400000001 to collect the value of the first road? Enter 010400000002, that is, the value of the first two roads input 010400000003, and the value of the first three roads, and so on!

Similar software comparison

      Serial port debugging toolIt is a tool software for serial debugging and tracking data. Support hexadecimal and ASC characters switching display. Can customize data sending. Send interval time can be adjusted. Have verification and calculation functions.

      TCP/UDP Socket debugging toolThe official version is a more practical socket debugging tool. The Socket debug assistant can help network programmer and network maintenance personnel check the communication status of the network application software and hardware developed by the network maintenance personnel. TCP/UDP The socket debugging tool also supports multi -SOCKET parallel test, using tree -shaped socket visualization interface.

Common problem


1. Connection problem

Unable to connect to the machine equipment

reason:

The settings of communication parameters such as Potter rate, data position, stop position, and verification are incorrect.

Error setting from the device ID (Device ID).

The external connection line is loose or damaged.

Solution:

Check and confirm that the communication parameter settings in Modscan32 are consistent with the machine equipment.

Confirm that the installation address settings are set correctly.

Check whether the external connection is firmly connected without damage.

MODBUS Message Time-OUT

reason:

Network delay or unstable.

The machine equipment is not responded or responded to timeout.

The communication protocol between Modscan32 and the machine equipment is not compatible.

Solution:

Check whether the network connection is stable.

Try to restart the machine equipment.

Confirm that the communication protocol (RTU or ASCII) settings between Modscan32 and the machine devices is correct.

2. Data reading and writing problems

Data reading is inaccurate

reason:

The register address or data type settings error.

Internal faults or data abnormalities from machine equipment.

Solution:

Check and confirm that the register address and data type settings in Modscan32 are correct.

Try to use other MODBUS debugging tools for verification.

Check whether the device runs normally and whether the data is accurate.

Unable to write data

reason:

From machine equipment does not support writing operations.

Write authority settings error.

The written data format or range does not meet the requirements of the machine equipment.

Solution:

Confirm the support of the equipment support from the machine equipment.

Check and revise the settings of the access authority.

Make sure the written data format and range meet the requirements of the machine equipment.

Xiaobian of Hua Jun:

Modbus debugging tool (Modscan32)Support Modbus protocol device debugging operations, you can receive important data information of the Modbus protocol. Modbus debugging tools (MODSCAN32) have become very stable and powerful after the official continuous update iterative iteration, which meets all your needs.

Version: 8.00 official version | Update time: 2024-09-14

Similar recommendation

Latest update

Modbus debugging tool (Modscan32) comments

  • 1st floor Huajun netizen 2021-10-30 23:44:18
    The Modbus debugging tool (Modscan32) interface design is easy to get started, and the function is very rich. I strongly recommend it!
  • 2nd floor Huajun netizen 2022-03-23 ​​07:17:19
    Modbus debugging tool (Modscan32) software is very easy to use, download speed is fast, very convenient!
  • 3rd floor Huajun netizen 2022-02-18 22:52:32
    Modbus debugging tool (Modscan32) is not bad, download is very fast, give you a praise!

Boutique recommendation

EveryoneStill likeThese:

+

The application has not passed the real -name authentication, you can download it through your mobile assistant.

CancelOK